{"id":10272,"date":"2012-04-23T02:04:32","date_gmt":"2012-04-23T02:04:32","guid":{"rendered":"http:\/\/cardiophile.org\/?p=7458"},"modified":"2012-04-23T02:04:32","modified_gmt":"2012-04-23T02:04:32","slug":"intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/","title":{"rendered":"Intrathoracic impedance monitoring with audible alert in heart failure management"},"content":{"rendered":"<h2><span style=\"color: #008000;\">Intrathoracic impedance monitoring with audible alert in heart failure management<\/span><\/h2>\n<p><em><strong>Intrathoracic impedance monitoring<\/strong> <\/em>with audible alert has been tried in heart failure management. This technology incorporated in heart failure devices {cardiac resynchronization therapy (CRT)} and implantable cardioverter-defibrillator (ICD) is used to assess the volume status and advice early hospitalization if needed. Dirk J van Veldhuisen, Frieder Braunschweig, Viviane Conraads, Ian Ford, Martin R Cowie, Guillaume Jondeau, Josef Kautzner and Roberto Mu\u00f1oz Aguilera, Maurizio Lunati, Cheuk Man Yu, Bart Gerritse, Martin Borggrefe the DOT-HF Investigators from the Department of Cardiology, University Medical Center Groningen, University of Groningen, Netherlands studied 335 patients with chronic heart failure who had undergone implantation of CRT or ICD [1].<\/p>\n<p>Heart failure patients get hospitalised frequently due to worsening of heart failure often associated with volume overload. Intrathoracic impedance measurement with an audible alert may give early indication of retention of fluid in the lungs and help patients seek medical advice before they become too sick.<\/p>\n<p>Of the 335 patients with chronic heart failure in the study, 18% had an ICD (implantable cardioverter defibrillator) alone while 82% had CRT (cardiac resynchronization therapy as well. All patients had intrathoracic impedance (OptiVol). They were randomized to have information available to physicians and patients as an audible alert in case preset threshold was crossed (access arm) or not (control arm).<\/p>\n<p>According to the authors, though the device increased heart failure hospitalizations and outpatient visits in heart failure patients, it did not improve the final outcome in terms of mortality or heart failure hospitalizations.<\/p>\n<p><strong><span style=\"color: #0000ff;\">Reference<\/span><\/strong><\/p>\n<ol>\n<li>Dirk J van Veldhuisen, Frieder Braunschweig, Viviane Conraads, Ian Ford, Martin R Cowie, Guillaume Jondeau, Josef Kautzner, Roberto Mu\u00f1oz Aguilera, Maurizio Lunati, Cheuk Man Yu, Bart Gerritse, Martin Borggrefe, DOT-HF Investigators. <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/21931078\">Intrathoracic Impedance Monitoring, Audible Patient Alerts, and Outcome in Patients With Heart Failure<\/a>. Circulation. 2011 Oct 18;124(16):1719-26.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Intra thoracic impedance monitoring with audible alert has been tried in heart failure management.<\/p>\n","protected":false},"author":1,"featured_media":35612,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[6],"tags":[],"class_list":["post-10272","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ecg-electrophysiology"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Intrathoracic impedance monitoring with audible alert in heart failure management - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"description\" content=\"Intrathoracic impedance monitoring with audible alert has been tried in heart failure management. It did not improve final outcome.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Intrathoracic impedance monitoring with audible alert in heart failure management - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"Intrathoracic impedance monitoring with audible alert has been tried in heart failure management. It did not improve final outcome.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2012-04-23T02:04:32+00:00\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Intrathoracic impedance monitoring with audible alert in heart failure management\",\"datePublished\":\"2012-04-23T02:04:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/\"},\"wordCount\":308,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"articleSection\":[\"ECG \\\/ Electrophysiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/\",\"name\":\"Intrathoracic impedance monitoring with audible alert in heart failure management - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2012-04-23T02:04:32+00:00\",\"description\":\"Intrathoracic impedance monitoring with audible alert has been tried in heart failure management. It did not improve final outcome.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Intrathoracic impedance monitoring with audible alert in heart failure management\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Intrathoracic impedance monitoring with audible alert in heart failure management - All About Cardiovascular System and Disorders","description":"Intrathoracic impedance monitoring with audible alert has been tried in heart failure management. It did not improve final outcome.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/","og_locale":"en_US","og_type":"article","og_title":"Intrathoracic impedance monitoring with audible alert in heart failure management - All About Cardiovascular System and Disorders","og_description":"Intrathoracic impedance monitoring with audible alert has been tried in heart failure management. It did not improve final outcome.","og_url":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2012-04-23T02:04:32+00:00","author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Intrathoracic impedance monitoring with audible alert in heart failure management","datePublished":"2012-04-23T02:04:32+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/"},"wordCount":308,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#primaryimage"},"thumbnailUrl":"","articleSection":["ECG \/ Electrophysiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/","url":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/","name":"Intrathoracic impedance monitoring with audible alert in heart failure management - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#primaryimage"},"thumbnailUrl":"","datePublished":"2012-04-23T02:04:32+00:00","description":"Intrathoracic impedance monitoring with audible alert has been tried in heart failure management. It did not improve final outcome.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/intra-thoracic-impedance-monitoring-with-audible-alert-in-heart-failure-management-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Intrathoracic impedance monitoring with audible alert in heart failure management"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/10272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=10272"}],"version-history":[{"count":0,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/10272\/revisions"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=10272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=10272"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=10272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}