{"id":123,"date":"2008-09-17T11:00:53","date_gmt":"2008-09-17T17:00:53","guid":{"rendered":"http:\/\/md.cardiophile.com\/?p=79"},"modified":"2008-09-17T11:00:53","modified_gmt":"2008-09-17T17:00:53","slug":"magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/","title":{"rendered":"Magnetic resonance imaging of pacemakers and implantable defibrillators"},"content":{"rendered":"<h2><span style=\"color: #008000;\">Magnetic resonance imaging of pacemakers and implantable defibrillators<\/span><\/h2>\n<p>Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, magnetic resonance imaging (MRI) is contraindicated in patients with implanted rhythm devices (pacemaker, implantable cardioverter defibrillator, insertable loop recorder). Earlier studies had shown that scanning at 0.5 &#8211; 1.5 Tesla field strength could be done cautiously in those with an absolute life saving requirement for an MRI scan. Now a recent study in PACE [1] has shown that it is possible to use even 3 Tesla MRI scanners with good safety. But extensive monitoring, pre and post programming and supervision by an electrophysiologist are mandatory. Moreover, the information to be gained by MRI should be so important in the management of the patient and not obtainable from other modalities. In this study on 14 patients, no significant change in the programmed parameters, pacing thresholds, sensing, impedance, or battery parameters was noted. Prolonged artifactual asystole was recorded by the insertable loop recorder (ILR) during the MRI scan. In general such scans are not considered in pacemaker dependent patients and in those with recently implanted pacemakers.<\/p>\n<p>The data presented here is about non MRI conditional cardiac implantable rhythm devices.<\/p>\n<p><span style=\"color: #0000ff;\"><strong>Reference<\/strong><\/span><\/p>\n<ol>\n<li>Gimbel JR. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/18684275\">Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla<\/a>.\u00a0Pacing Clin Electrophysiol. 2008 Jul;31(7):795-801.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Magnetic resonance imaging of pacemakers and implantable defibrillators <\/p>\n","protected":false},"author":1,"featured_media":31622,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[6],"tags":[],"class_list":["post-123","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ecg-electrophysiology"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Magnetic resonance imaging of pacemakers and implantable defibrillators<\/title>\n<meta name=\"description\" content=\"Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, contraindicated, can be considered with specific precautions.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Magnetic resonance imaging of pacemakers and implantable defibrillators\" \/>\n<meta property=\"og:description\" content=\"Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, contraindicated, can be considered with specific precautions.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2008-09-17T17:00:53+00:00\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Magnetic resonance imaging of pacemakers and implantable defibrillators\",\"datePublished\":\"2008-09-17T17:00:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/\"},\"wordCount\":215,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"articleSection\":[\"ECG \\\/ Electrophysiology\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/\",\"name\":\"Magnetic resonance imaging of pacemakers and implantable defibrillators\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2008-09-17T17:00:53+00:00\",\"description\":\"Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, contraindicated, can be considered with specific precautions.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Magnetic resonance imaging of pacemakers and implantable defibrillators\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Magnetic resonance imaging of pacemakers and implantable defibrillators","description":"Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, contraindicated, can be considered with specific precautions.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/","og_locale":"en_US","og_type":"article","og_title":"Magnetic resonance imaging of pacemakers and implantable defibrillators","og_description":"Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, contraindicated, can be considered with specific precautions.","og_url":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2008-09-17T17:00:53+00:00","author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Magnetic resonance imaging of pacemakers and implantable defibrillators","datePublished":"2008-09-17T17:00:53+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/"},"wordCount":215,"commentCount":0,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#primaryimage"},"thumbnailUrl":"","articleSection":["ECG \/ Electrophysiology"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/","url":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/","name":"Magnetic resonance imaging of pacemakers and implantable defibrillators","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#primaryimage"},"thumbnailUrl":"","datePublished":"2008-09-17T17:00:53+00:00","description":"Magnetic resonance imaging of pacemakers and implantable defibrillators: Conventionally, contraindicated, can be considered with specific precautions.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/magnetic-resonance-imaging-of-pacemakers-and-implantable-defibrillators\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Magnetic resonance imaging of pacemakers and implantable defibrillators"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=123"}],"version-history":[{"count":0,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/123\/revisions"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=123"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=123"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}