{"id":12606,"date":"2014-07-25T09:20:53","date_gmt":"2014-07-25T09:20:53","guid":{"rendered":"http:\/\/cardiophile.org\/?p=12606"},"modified":"2023-03-13T17:58:36","modified_gmt":"2023-03-13T12:28:36","slug":"aortic-gradient-assessment-by-doppler-echo","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/","title":{"rendered":"Aortic Gradient Assessment by Doppler Echo"},"content":{"rendered":"<p><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/6h6Si-mC9oU\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"><\/iframe><\/p>\n<h2><span style=\"color: #008000;\">Aortic gradient assessment by Doppler echo<\/span><\/h2>\n<figure id=\"attachment_12607\" aria-describedby=\"caption-attachment-12607\" style=\"width: 500px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-gradient.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-12607\" src=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-gradient.jpg\" alt=\"Aortic gradient by Doppler echo\" width=\"500\" height=\"294\" srcset=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-gradient.jpg 500w, https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-gradient-300x176.jpg 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><figcaption id=\"caption-attachment-12607\" class=\"wp-caption-text\">Aortic gradient by Doppler echo<\/figcaption><\/figure>\n<p>Normal gradient across aortic valve can be measured by pulsed Doppler echocardiography as the gradients are low. In the presence of aortic stenosis, the gradients are high and needs continuous wave Doppler or high pulse repetition pulsed Doppler to measure trans aortic gradient as the velocities are above the Nyquist limit of conventional pulsed Doppler echo.<\/p>\n<p>Nyquist limit will be half the pulse repetition frequency. Hence it will be low for conventional pulsed Doppler with low pulse repetition frequency and high for high pulse repetition pulsed Doppler. Theoretically it is infinite for continuous wave Doppler.<\/p>\n<p>In this image measurement of aortic peak gradient and mean gradient are illustrated. The early diastolic E and late diastolic A waves of mitral inflow are also demonstrated. Peak aortic gradient and mean aortic gradient are mildly elevated in this case. Such mild elevation of trans aortic gradients may be noted in hyperdynamic states like severe aortic regurgitation.<\/p>\n<p>But here there is no aortic regurgitation seen on Doppler echo.&nbsp;Similar gradients may also be seen across normally functioning prosthetic aortic valves. This is because any prosthetic valve in aortic location can intrinsically narrow the left ventricular outflow tract mildly, depending on the profile of the valve.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Aortic gradient assessment by Doppler echo Normal gradient across aortic valve can be measured by pulsed Doppler echocardiography as the gradients are low. In the presence of aortic stenosis, the gradients are high and needs continuous wave Doppler or high pulse repetition pulsed Doppler to measure trans aortic gradient as the velocities are above the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":58893,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[25,8],"tags":[269,271,280,881,2617,2646,3156,3158,3159],"class_list":["post-12606","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-echocardiogram-library-echocardiogram-library","category-echocardiogram-library","tag-aortic-mean-gradient","tag-aortic-peak-gradient","tag-aortic-stenosis","tag-continuous-wave-doppler","tag-normal-gradient-across-aortic-valve","tag-nyquist-limit","tag-pulse-repetition-frequency","tag-pulsed-doppler","tag-pulsed-doppler-echocardiography"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aortic Gradient Assessment by Doppler Echo - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"description\" content=\"Aortic gradient assessment by Doppler echo: Lower gradients across normal valve can be measured by pulsed Doppler; needs continuous wave in aortic stenosis\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aortic Gradient Assessment by Doppler Echo - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"Aortic gradient assessment by Doppler echo: Lower gradients across normal valve can be measured by pulsed Doppler; needs continuous wave in aortic stenosis\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2014-07-25T09:20:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-13T12:28:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"898\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Aortic Gradient Assessment by Doppler Echo\",\"datePublished\":\"2014-07-25T09:20:53+00:00\",\"dateModified\":\"2023-03-13T12:28:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/\"},\"wordCount\":226,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg\",\"keywords\":[\"aortic mean gradient\",\"aortic peak gradient\",\"Aortic stenosis\",\"continuous wave Doppler\",\"Normal gradient across aortic valve\",\"Nyquist limit\",\"pulse repetition frequency\",\"Pulsed Doppler\",\"pulsed Doppler echocardiography\"],\"articleSection\":[\"Echocardiogram Library\",\"Echocardiography\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/\",\"name\":\"Aortic Gradient Assessment by Doppler Echo - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg\",\"datePublished\":\"2014-07-25T09:20:53+00:00\",\"dateModified\":\"2023-03-13T12:28:36+00:00\",\"description\":\"Aortic gradient assessment by Doppler echo: Lower gradients across normal valve can be measured by pulsed Doppler; needs continuous wave in aortic stenosis\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg\",\"width\":1200,\"height\":898},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/aortic-gradient-assessment-by-doppler-echo\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aortic Gradient Assessment by Doppler Echo\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aortic Gradient Assessment by Doppler Echo - All About Cardiovascular System and Disorders","description":"Aortic gradient assessment by Doppler echo: Lower gradients across normal valve can be measured by pulsed Doppler; needs continuous wave in aortic stenosis","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/","og_locale":"en_US","og_type":"article","og_title":"Aortic Gradient Assessment by Doppler Echo - All About Cardiovascular System and Disorders","og_description":"Aortic gradient assessment by Doppler echo: Lower gradients across normal valve can be measured by pulsed Doppler; needs continuous wave in aortic stenosis","og_url":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2014-07-25T09:20:53+00:00","article_modified_time":"2023-03-13T12:28:36+00:00","og_image":[{"width":1200,"height":898,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Aortic Gradient Assessment by Doppler Echo","datePublished":"2014-07-25T09:20:53+00:00","dateModified":"2023-03-13T12:28:36+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/"},"wordCount":226,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg","keywords":["aortic mean gradient","aortic peak gradient","Aortic stenosis","continuous wave Doppler","Normal gradient across aortic valve","Nyquist limit","pulse repetition frequency","Pulsed Doppler","pulsed Doppler echocardiography"],"articleSection":["Echocardiogram Library","Echocardiography"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/","url":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/","name":"Aortic Gradient Assessment by Doppler Echo - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg","datePublished":"2014-07-25T09:20:53+00:00","dateModified":"2023-03-13T12:28:36+00:00","description":"Aortic gradient assessment by Doppler echo: Lower gradients across normal valve can be measured by pulsed Doppler; needs continuous wave in aortic stenosis","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Aortic-Gradient-Assessment-by-Doppler-Echo.jpg","width":1200,"height":898},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/aortic-gradient-assessment-by-doppler-echo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Aortic Gradient Assessment by Doppler Echo"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/12606","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=12606"}],"version-history":[{"count":5,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/12606\/revisions"}],"predecessor-version":[{"id":58898,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/12606\/revisions\/58898"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/58893"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=12606"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=12606"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=12606"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}