{"id":12689,"date":"2014-07-27T11:34:47","date_gmt":"2014-07-27T11:34:47","guid":{"rendered":"http:\/\/cardiophile.org\/?p=12689"},"modified":"2014-07-27T11:34:47","modified_gmt":"2014-07-27T11:34:47","slug":"dual-zone-programming-reduces-inappropriate-s-icd-shocks","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/","title":{"rendered":"Dual zone programming reduces inappropriate S-ICD shocks"},"content":{"rendered":"<h2><span style=\"color: #008000;\">Dual zone programming reduces inappropriate S-ICD shocks<\/span><\/h2>\n<p><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/smO13w1baao\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"><\/iframe><\/p>\n<p>Dual zone ICD programming: Inappropriate shocks are an important adverse effects of life saving implantable cardioverter defibrillators (ICD). Subcutaneous ICDs with no intra cardiac leads (S-ICD) are not immune from this adverse effect. A new algorithm to reduce inappropriate shocks by programming two zones &#8211; one shock zone and another with an arrhythmia discrimination algorithm at lower rates (conditional shock zone programming). Michael R Gold, Raul Weiss, Dominic A M J Theuns, Warren Smith, Angel Leon, Bradley P Knight, Nathan Carter, Michael Husby and Martin C Burke showed that adding an additional zone with arrhythmia discrimination reduces the inappropriate shocks from about twenty six percent to around ten percent in a study involving about three hundred patients over two years [1]. There was no difference in the freedom from appropriate shocks between the groups, nor there was a difference in the mean time to appropriate therapy. It is noteworthy that there was no increased incidence of syncope with dual zone therapy. There was only one episode of arrhythmic syncope in the cohort.<\/p>\n<p>Usual programming has only a single zone for giving shocks based strictly on heart rate criteria without any rhythm discrimination. In the conditional shock zone, rhythm discrimination algorithm can classify rhythms which needs a shock vs those that do not need shock when it is deemed to be supraventricular.<\/p>\n<p><strong><span style=\"color: #0000ff;\">Reference<\/span><\/strong><\/p>\n<ol>\n<li>Michael R Gold, Raul Weiss, Dominic A M J Theuns, Warren Smith, Angel Leon, Bradley P Knight, Nathan Carter, Michael Husby, Martin C Burke. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/24732366\/\">Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator<\/a>. Heart Rhythm. 2014 Aug;11(8):1352-8.<\/li>\n<\/ol>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dual zone programming reduces inappropriate S-ICD shocks Dual zone ICD programming: Inappropriate shocks are an important adverse effects of life saving implantable cardioverter defibrillators (ICD). Subcutaneous ICDs with no intra cardiac leads (S-ICD) are not immune from this adverse effect. A new algorithm to reduce inappropriate shocks by programming two zones &#8211; one shock zone [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":34198,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[6],"tags":[321,858,1226,1544,1767,1799,2317,3259,3462,3555,3750,3751],"class_list":["post-12689","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ecg-electrophysiology","tag-arrhythmia-discrimination-algorithm","tag-conditional-shock-zone-programming","tag-dual-zone-programming","tag-freedom-from-appropriate-shocks","tag-icd","tag-implantable-cardioverter-defibrillators","tag-mean-time-to-appropriate-therapy","tag-reduction-of-inappropriate-icd-shocks","tag-s-icd","tag-shock-zone","tag-subcutaneous-icd","tag-subcutaneous-implantable-cardioverter-defibrillator"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Dual zone programming reduces inappropriate S-ICD shocks - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"description\" content=\"Dual zone ICD programming reduces inappropriate S-ICD shocks, without an difference in mean time to appropriate therapy or appropriate shocks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dual zone programming reduces inappropriate S-ICD shocks - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"Dual zone ICD programming reduces inappropriate S-ICD shocks, without an difference in mean time to appropriate therapy or appropriate shocks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2014-07-27T11:34:47+00:00\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Dual zone programming reduces inappropriate S-ICD shocks\",\"datePublished\":\"2014-07-27T11:34:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/\"},\"wordCount\":277,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"keywords\":[\"arrhythmia discrimination algorithm\",\"conditional shock zone programming\",\"Dual zone programming\",\"freedom from appropriate shocks\",\"ICD\",\"Implantable cardioverter defibrillators\",\"mean time to appropriate therapy\",\"reduction of inappropriate ICD shocks\",\"S-ICD\",\"shock zone\",\"Subcutaneous ICD\",\"subcutaneous implantable cardioverter-defibrillator\"],\"articleSection\":[\"ECG \\\/ Electrophysiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/\",\"name\":\"Dual zone programming reduces inappropriate S-ICD shocks - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2014-07-27T11:34:47+00:00\",\"description\":\"Dual zone ICD programming reduces inappropriate S-ICD shocks, without an difference in mean time to appropriate therapy or appropriate shocks.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Dual zone programming reduces inappropriate S-ICD shocks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Dual zone programming reduces inappropriate S-ICD shocks - All About Cardiovascular System and Disorders","description":"Dual zone ICD programming reduces inappropriate S-ICD shocks, without an difference in mean time to appropriate therapy or appropriate shocks.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/","og_locale":"en_US","og_type":"article","og_title":"Dual zone programming reduces inappropriate S-ICD shocks - All About Cardiovascular System and Disorders","og_description":"Dual zone ICD programming reduces inappropriate S-ICD shocks, without an difference in mean time to appropriate therapy or appropriate shocks.","og_url":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2014-07-27T11:34:47+00:00","author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Dual zone programming reduces inappropriate S-ICD shocks","datePublished":"2014-07-27T11:34:47+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/"},"wordCount":277,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#primaryimage"},"thumbnailUrl":"","keywords":["arrhythmia discrimination algorithm","conditional shock zone programming","Dual zone programming","freedom from appropriate shocks","ICD","Implantable cardioverter defibrillators","mean time to appropriate therapy","reduction of inappropriate ICD shocks","S-ICD","shock zone","Subcutaneous ICD","subcutaneous implantable cardioverter-defibrillator"],"articleSection":["ECG \/ Electrophysiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/","url":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/","name":"Dual zone programming reduces inappropriate S-ICD shocks - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#primaryimage"},"thumbnailUrl":"","datePublished":"2014-07-27T11:34:47+00:00","description":"Dual zone ICD programming reduces inappropriate S-ICD shocks, without an difference in mean time to appropriate therapy or appropriate shocks.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/dual-zone-programming-reduces-inappropriate-s-icd-shocks\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Dual zone programming reduces inappropriate S-ICD shocks"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/12689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=12689"}],"version-history":[{"count":0,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/12689\/revisions"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=12689"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=12689"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=12689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}