{"id":13006,"date":"2014-07-30T12:25:50","date_gmt":"2014-07-30T12:25:50","guid":{"rendered":"http:\/\/cardiophile.org\/?p=13006"},"modified":"2023-02-01T22:21:55","modified_gmt":"2023-02-01T16:51:55","slug":"brachial-artery-flow-mediated-vasodilation","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/","title":{"rendered":"Brachial artery flow mediated vasodilation"},"content":{"rendered":"<p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/vYNCyJqdgys\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<h2><span style=\"color: #008000;\"><strong>Brachial artery flow mediated vasodilation<\/strong><\/span><\/h2>\n<p>Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside. It is a method of provoking release of the potent vasodilator nitric oxide non invasively and measuring its vascular response at the bedside.<\/p>\n<p>A segment of brachial artery is measured by ultrasound and proximal occlusion is applied for a period of 5 minutes. Repeated measurement is taken after 1 minute and within 10 minutes, to assess the flow mediated vasodilation. More than 10% increase in vessel diameter is taken as a positive response.<\/p>\n<p>It may be technically challenging to get good brachial artery images with proximal occlusion which can distort the vessel. Alternative method of induction of distal ischemia, the main vasodilatory stimulus, is by inflating cuff in forearm [1].<\/p>\n<p>As the vascular response may be affected by food, drugs, temperature and sympathetic stimuli, certain precautions are needed. Overnight fasting before the test is recommended. All medications acting on the blood vessels have to be withdrawn for an adequate wash out period.<\/p>\n<p>High fat foods, caffeine, vitamin C and tobacco can affect the flow mediated vasodilation and are avoided in the preceding six hours. Study should be conducted in a quiet, temperature controlled room. A linear array ultrasound transducer of at least 7 MHz frequency is used along with ECG triggering.<\/p>\n<p><span style=\"color: #0000ff;\"><strong>Reference<\/strong><\/span><\/p>\n<ol>\n<li>Mary C Corretti, Todd J Anderson, Emelia J Benjamin, David Celermajer, Francois Charbonneau, Mark A Creager, John Deanfield, Helmut Drexler, Marie Gerhard-Herman, David Herrington, Patrick Vallance, Joseph Vita, Robert Vogel, International Brachial Artery Reactivity Task Force. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/11788217\/\">Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery<\/a>. J Am Coll Cardiol. 2002;39(2):257-265.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.<\/p>\n","protected":false},"author":1,"featured_media":58418,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[9],"tags":[470,551,1369,1370,1517,2565,2569,2584,4090],"class_list":["post-13006","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","tag-bedside-evaluation-of-endothelial-function","tag-brachial-artery-flow-mediated-vasodilation","tag-endothelial-nitric-oxide-synthase","tag-endothelial-dependent-flow-mediated-vasodilation","tag-flow-mediated-vasodilation","tag-nitric-oxide","tag-no","tag-non-invasive-assessment-of-endothelial-function","tag-ultrasound-assessment"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Brachial artery flow mediated vasodilation to assess endothelial function<\/title>\n<meta name=\"description\" content=\"Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Brachial artery flow mediated vasodilation to assess endothelial function\" \/>\n<meta property=\"og:description\" content=\"Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2014-07-30T12:25:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-02-01T16:51:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"897\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Brachial artery flow mediated vasodilation\",\"datePublished\":\"2014-07-30T12:25:50+00:00\",\"dateModified\":\"2023-02-01T16:51:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/\"},\"wordCount\":280,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg\",\"keywords\":[\"bedside evaluation of endothelial function\",\"Brachial artery flow mediated vasodilation\",\"endothelial nitric oxide synthase\",\"endothelial-dependent flow-mediated vasodilation\",\"flow mediated vasodilation\",\"nitric oxide\",\"NO\",\"non invasive assessment of endothelial function\",\"ultrasound assessment\"],\"articleSection\":[\"General Cardiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/\",\"name\":\"Brachial artery flow mediated vasodilation to assess endothelial function\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg\",\"datePublished\":\"2014-07-30T12:25:50+00:00\",\"dateModified\":\"2023-02-01T16:51:55+00:00\",\"description\":\"Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/07\\\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg\",\"width\":1200,\"height\":897},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/brachial-artery-flow-mediated-vasodilation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Brachial artery flow mediated vasodilation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Brachial artery flow mediated vasodilation to assess endothelial function","description":"Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/","og_locale":"en_US","og_type":"article","og_title":"Brachial artery flow mediated vasodilation to assess endothelial function","og_description":"Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.","og_url":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2014-07-30T12:25:50+00:00","article_modified_time":"2023-02-01T16:51:55+00:00","og_image":[{"width":1200,"height":897,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Brachial artery flow mediated vasodilation","datePublished":"2014-07-30T12:25:50+00:00","dateModified":"2023-02-01T16:51:55+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/"},"wordCount":280,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg","keywords":["bedside evaluation of endothelial function","Brachial artery flow mediated vasodilation","endothelial nitric oxide synthase","endothelial-dependent flow-mediated vasodilation","flow mediated vasodilation","nitric oxide","NO","non invasive assessment of endothelial function","ultrasound assessment"],"articleSection":["General Cardiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/","url":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/","name":"Brachial artery flow mediated vasodilation to assess endothelial function","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg","datePublished":"2014-07-30T12:25:50+00:00","dateModified":"2023-02-01T16:51:55+00:00","description":"Brachial artery flow mediated vasodilation is considered to be an important way to assess the endothelial function on the bedside.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/07\/Brachial-Artery-Flow-Mediated-Vasodilation.jpg","width":1200,"height":897},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/brachial-artery-flow-mediated-vasodilation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Brachial artery flow mediated vasodilation"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/13006","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=13006"}],"version-history":[{"count":4,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/13006\/revisions"}],"predecessor-version":[{"id":58420,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/13006\/revisions\/58420"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/58418"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=13006"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=13006"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=13006"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}