{"id":13866,"date":"2014-08-18T16:36:20","date_gmt":"2014-08-18T16:36:20","guid":{"rendered":"http:\/\/cardiophile.org\/?p=13866"},"modified":"2023-01-22T11:05:31","modified_gmt":"2023-01-22T05:35:31","slug":"invasive-blood-pressure-monitoring","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/","title":{"rendered":"Invasive blood pressure monitoring"},"content":{"rendered":"<p><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dMgh4PfqOOE\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"><\/iframe><\/p>\n<h2>Invasive blood pressure monitoring<\/h2>\n<h2><span style=\"color: #3366ff;\">Illustrated notes<\/span><\/h2>\n<p><a href=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/invasive-pressure-monitoring.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-14141\" src=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/invasive-pressure-monitoring.jpg\" alt=\"invasive pressure monitoring\" width=\"533\" height=\"316\" srcset=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/invasive-pressure-monitoring.jpg 533w, https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/invasive-pressure-monitoring-300x178.jpg 300w\" sizes=\"auto, (max-width: 533px) 100vw, 533px\" \/><\/a>Invasive blood pressure monitoring is fairly common in the acute care setting. A small cannula is introduced percutaneously into the radial artery or any other artery which is easily accessible and the proximal end connected to the pressure transducer through a three way stop cock system. A <strong>high pressure drip<\/strong> attached to one port of the three way system allows continuous flushing of the system at a slow rate of around 3 ml per hour.<\/p>\n<p>The fluid to be used for flushing is kept in a sterile collapsible bag and the bag is encased by a pressure delivery system or pressure infusion bag. The pressure within the enclosure can be raised to 300 mm Hg and is demonstrated by the indicator piston progressively coming out with initial marking at 150 mm Hg and the next marking at 300 mm Hg. Both these marks are coloured green while beyond this level the markings are in red and in some systems there is provision for automatic deflation to lower levels when the pressure is raised beyond the permissible level.<\/p>\n<figure id=\"attachment_58241\" aria-describedby=\"caption-attachment-58241\" style=\"width: 640px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-58241 size-large\" src=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Pressure-infusion-bag-and-pressure-indicator-1024x528.jpg\" alt=\"Pressure infusion bag and pressure indicator\" width=\"640\" height=\"330\" srcset=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Pressure-infusion-bag-and-pressure-indicator-1024x528.jpg 1024w, https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Pressure-infusion-bag-and-pressure-indicator-300x155.jpg 300w, https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Pressure-infusion-bag-and-pressure-indicator-768x396.jpg 768w, https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Pressure-infusion-bag-and-pressure-indicator.jpg 1145w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><figcaption id=\"caption-attachment-58241\" class=\"wp-caption-text\">Pressure infusion bag and pressure indicator<\/figcaption><\/figure>\n<p>Pressure within the bag is raised using a mechanism similar to the bellows of the sphygmomanometer. There is a flushing valve for the transducer assembly which can be used to flush the cannula with higher flow rate if needed, to relieve any partial obstruction due to clot formation. When a small handle of the flushing port is pulled out the drip flows fast as the whole 300 mmHg compression force is freely delivered to the infusion system. Small amount of heparin is added to the flush solution, usually normal saline, to prevent clot formation at the tip of the cannula within the artery.<\/p>\n<p>Invasive monitors usually display ECG, pulse oximetry tracing and respiration along with the invasive blood pressure. End tidal carbon dioxide or ETCO2 module can also be incorporated when needed, mostly in patients on intermittent positive pressure ventilation.<\/p>\n<p>In the picture shown here, the violet tracing represents the ECG and green tracing the invasive intra arterial blood pressure. The heart rate is displayed as 86 per minute and blood pressure as 106\/63 mm Hg with a mean arterial pressure of 78 mm Hg. Very often in the critical care setting the intensivists depend on mean arterial pressure to titrate the dose of pressor agents while treating shock.<\/p>\n<p>If the <strong>invasive arterial tracing<\/strong> does not show a good wave form, the cannula has to be flushed. If still the pressure tracing is not good, it may be worthwhile changing the site of the arterial cannula.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.<\/p>\n","protected":false},"author":1,"featured_media":58243,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[9],"tags":[1696,1921,1923,2999,3163,3290],"class_list":["post-13866","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","tag-high-pressure-drip","tag-invasive-arterial-tracing","tag-invasive-blood-pressure-monitoring","tag-pressure-transducer","tag-pulsoximetry-tracing","tag-respiration-measured-using-thoracic-impedance"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Invasive blood pressure monitoring<\/title>\n<meta name=\"description\" content=\"Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Invasive blood pressure monitoring\" \/>\n<meta property=\"og:description\" content=\"Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2014-08-18T16:36:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-01-22T05:35:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Invasive-blood-pressure-monitoring.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"895\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Invasive blood pressure monitoring\",\"datePublished\":\"2014-08-18T16:36:20+00:00\",\"dateModified\":\"2023-01-22T05:35:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/\"},\"wordCount\":438,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/08\\\/Invasive-blood-pressure-monitoring.jpg\",\"keywords\":[\"high pressure drip\",\"invasive arterial tracing\",\"Invasive blood pressure monitoring\",\"pressure transducer\",\"pulsoximetry tracing\",\"respiration measured using thoracic impedance\"],\"articleSection\":[\"General Cardiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/\",\"name\":\"Invasive blood pressure monitoring\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/08\\\/Invasive-blood-pressure-monitoring.jpg\",\"datePublished\":\"2014-08-18T16:36:20+00:00\",\"dateModified\":\"2023-01-22T05:35:31+00:00\",\"description\":\"Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/08\\\/Invasive-blood-pressure-monitoring.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2014\\\/08\\\/Invasive-blood-pressure-monitoring.jpg\",\"width\":1200,\"height\":895},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/invasive-blood-pressure-monitoring\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Invasive blood pressure monitoring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Invasive blood pressure monitoring","description":"Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/","og_locale":"en_US","og_type":"article","og_title":"Invasive blood pressure monitoring","og_description":"Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.","og_url":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2014-08-18T16:36:20+00:00","article_modified_time":"2023-01-22T05:35:31+00:00","og_image":[{"width":1200,"height":895,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Invasive-blood-pressure-monitoring.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Invasive blood pressure monitoring","datePublished":"2014-08-18T16:36:20+00:00","dateModified":"2023-01-22T05:35:31+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/"},"wordCount":438,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Invasive-blood-pressure-monitoring.jpg","keywords":["high pressure drip","invasive arterial tracing","Invasive blood pressure monitoring","pressure transducer","pulsoximetry tracing","respiration measured using thoracic impedance"],"articleSection":["General Cardiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/","url":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/","name":"Invasive blood pressure monitoring","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Invasive-blood-pressure-monitoring.jpg","datePublished":"2014-08-18T16:36:20+00:00","dateModified":"2023-01-22T05:35:31+00:00","description":"Invasive blood pressure monitoring is fairly common in acute care setting, using a small cannula in radial artery connected to a pressure transducer system.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Invasive-blood-pressure-monitoring.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2014\/08\/Invasive-blood-pressure-monitoring.jpg","width":1200,"height":895},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/invasive-blood-pressure-monitoring\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Invasive blood pressure monitoring"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/13866","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=13866"}],"version-history":[{"count":5,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/13866\/revisions"}],"predecessor-version":[{"id":58248,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/13866\/revisions\/58248"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/58243"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=13866"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=13866"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=13866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}