{"id":62736,"date":"2024-02-18T11:55:33","date_gmt":"2024-02-18T06:25:33","guid":{"rendered":"https:\/\/johnsonfrancis.org\/professional\/?p=62736"},"modified":"2024-02-18T20:43:56","modified_gmt":"2024-02-18T15:13:56","slug":"requirements-for-re-entry","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/","title":{"rendered":"Requirements for Re-entry"},"content":{"rendered":"<p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/-gYRf5D8tgU?si=f6uZxX86VoIrv8W8\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><br \/>\nThese are the basic requirements for re-entry in cardiac electrophysiology:<\/p>\n<ol>\n<li>The impulse should re-excite the same area again and again repeatedly<\/li>\n<li>The impulse should find the same area excitable when it reaches back<\/li>\n<li>The area should have sufficient time to recover<\/li>\n<li>The impulse should be constrained or directed to reach back to the same area<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>These are the basic requirements for re-entry in cardiac electrophysiology: The impulse should re-excite the same area again and again repeatedly The impulse should find the same area excitable when it reaches back The area should have sufficient time to recover The impulse should be constrained or directed to reach back to the same area<\/p>\n","protected":false},"author":1,"featured_media":62738,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[6,9],"tags":[],"class_list":["post-62736","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ecg-electrophysiology","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Requirements for Re-entry - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Requirements for Re-entry - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"These are the basic requirements for re-entry in cardiac electrophysiology: The impulse should re-excite the same area again and again repeatedly The impulse should find the same area excitable when it reaches back The area should have sufficient time to recover The impulse should be constrained or directed to reach back to the same area\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-18T06:25:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-18T15:13:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2024\/02\/Requirements-for-Re-entry.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"894\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Requirements for Re-entry\",\"datePublished\":\"2024-02-18T06:25:33+00:00\",\"dateModified\":\"2024-02-18T15:13:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/\"},\"wordCount\":58,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Requirements-for-Re-entry.jpg\",\"articleSection\":[\"ECG \\\/ Electrophysiology\",\"General Cardiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/\",\"name\":\"Requirements for Re-entry - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Requirements-for-Re-entry.jpg\",\"datePublished\":\"2024-02-18T06:25:33+00:00\",\"dateModified\":\"2024-02-18T15:13:56+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Requirements-for-Re-entry.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Requirements-for-Re-entry.jpg\",\"width\":1200,\"height\":894},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/requirements-for-re-entry\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Requirements for Re-entry\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Requirements for Re-entry - All About Cardiovascular System and Disorders","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/","og_locale":"en_US","og_type":"article","og_title":"Requirements for Re-entry - All About Cardiovascular System and Disorders","og_description":"These are the basic requirements for re-entry in cardiac electrophysiology: The impulse should re-excite the same area again and again repeatedly The impulse should find the same area excitable when it reaches back The area should have sufficient time to recover The impulse should be constrained or directed to reach back to the same area","og_url":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2024-02-18T06:25:33+00:00","article_modified_time":"2024-02-18T15:13:56+00:00","og_image":[{"width":1200,"height":894,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2024\/02\/Requirements-for-Re-entry.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Requirements for Re-entry","datePublished":"2024-02-18T06:25:33+00:00","dateModified":"2024-02-18T15:13:56+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/"},"wordCount":58,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2024\/02\/Requirements-for-Re-entry.jpg","articleSection":["ECG \/ Electrophysiology","General Cardiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/","url":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/","name":"Requirements for Re-entry - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2024\/02\/Requirements-for-Re-entry.jpg","datePublished":"2024-02-18T06:25:33+00:00","dateModified":"2024-02-18T15:13:56+00:00","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2024\/02\/Requirements-for-Re-entry.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2024\/02\/Requirements-for-Re-entry.jpg","width":1200,"height":894},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/requirements-for-re-entry\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Requirements for Re-entry"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/62736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=62736"}],"version-history":[{"count":4,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/62736\/revisions"}],"predecessor-version":[{"id":62741,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/62736\/revisions\/62741"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/62738"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=62736"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=62736"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=62736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}