{"id":66411,"date":"2026-03-12T06:53:04","date_gmt":"2026-03-12T01:23:04","guid":{"rendered":"https:\/\/johnsonfrancis.org\/professional\/?p=66411"},"modified":"2026-03-12T06:53:06","modified_gmt":"2026-03-12T01:23:06","slug":"coronary-in-stent-restenosis-isr","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/","title":{"rendered":"Coronary In-Stent Restenosis (ISR)"},"content":{"rendered":"<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/1OnBhV5NQuw?si=J5xXxAfukUbnGjux\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n\n<p id=\"p-rc_bea3b07286620117-27\" class=\"wp-block-paragraph\">In-stent restenosis (ISR) remains a significant challenge in interventional cardiology, characterized by the narrowing of a previously stented coronary artery segment.<sup><\/sup> While Drug-Eluting Stents (DES) have drastically reduced its incidence compared to Bare-Metal Stents (BMS), it still occurs in roughly <strong>5\u201310%<\/strong> of modern DES implantations.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Pathophysiology<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The underlying mechanism of ISR is essentially an exaggerated &#8220;healing&#8221; response to the vascular injury caused by stent deployment.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Neointimal Hyperplasia:<\/strong> This is the primary driver. The mechanical trauma of the stent causes endothelial denudation and inflammation. This triggers smooth muscle cell (SMC) proliferation and the migration of these cells into the subendothelial space, where they produce an extracellular matrix that narrows the lumen.<\/li>\n\n\n\n<li class=\"\"><strong>Neoatherosclerosis:<\/strong> More common in DES than BMS. Over time (months to years), the new endothelial layer remains dysfunctional, allowing lipid accumulation and the development of &#8220;new&#8221; atherosclerotic plaques\u2014including thin-cap fibroatheromas\u2014within the stent.<\/li>\n\n\n\n<li class=\"\"><strong>Mechanical Factors:<\/strong> Stent underexpansion (the most common mechanical cause), stent fracture, or non-uniform strut distribution can create local flow disturbances that promote restenosis.<\/li>\n\n\n\n<li class=\"\"><strong>Biological Factors:<\/strong> Hypersensitivity to the stent metal (e.g., nickel) or the polymer coating on a DES can drive localized chronic inflammation.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Clinical Presentation<\/h3>\n\n\n\n<p id=\"p-rc_bea3b07286620117-31\" class=\"wp-block-paragraph\">The presentation of ISR can range from silent findings on surveillance imaging to acute life-threatening events.<sup><\/sup><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Chronic Stable Angina:<\/strong> The most frequent presentation. Patients typically describe a gradual return of exertional chest pain or dyspnea on exertion.<\/li>\n\n\n\n<li class=\"\"><strong>Acute Coronary Syndrome (ACS):<\/strong> Approximately <strong>20\u201330%<\/strong> of ISR cases present as ACS (Unstable Angina or NSTEMI). This is often linked to <strong>neoatherosclerosis<\/strong>, where the plaque within the stent ruptures, just as it would in a native vessel.<\/li>\n\n\n\n<li class=\"\"><strong>Silent Ischemia:<\/strong> Detected during routine stress testing or follow-up angiography in high-risk patients.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h3 class=\"wp-block-heading\">Classification<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Clinicians often use this to describe the pattern of ISR <a href=\"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.cir.100.18.1872\" type=\"link\" id=\"https:\/\/www.ahajournals.org\/doi\/full\/10.1161\/01.cir.100.18.1872\">(Mehran Classification)<\/a>:<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li class=\"\"><strong>Pattern I:<\/strong> Focal (length \u2264 10 mm).<\/li>\n\n\n\n<li class=\"\"><strong>Pattern II:<\/strong> Diffuse intrastent (length &gt; 10 mm, confined to the stent).<\/li>\n\n\n\n<li class=\"\"><strong>Pattern III:<\/strong> Proliferative (length &gt; 10 mm, extending beyond stent edges).<\/li>\n\n\n\n<li class=\"\"><strong>Pattern IV:<\/strong> Total occlusion. TIMI flow grade of 0.<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">Management<\/h3>\n\n\n\n<p id=\"p-rc_bea3b07286620117-33\" class=\"wp-block-paragraph\">Management strategies are increasingly guided by <strong>Intravascular Imaging (IVUS or OCT)<\/strong> to determine the underlying cause (e.g., underexpansion vs. tissue hyperplasia).<sup><\/sup><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">A. Initial Optimization<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">If <strong>stent underexpansion<\/strong> is identified via imaging, high-pressure balloon angioplasty using non-compliant (NC) balloons is the first step to properly seat the original stent.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">B. Pharmacological\/Interventional Strategies<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Strategy<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Drug-Coated Balloons (DCB)<\/strong><\/td><td>Delivers antiproliferative drugs (e.g., Paclitaxel) directly to the vessel wall without adding a new layer of metal. This is often the preferred &#8220;leave nothing behind&#8221; strategy for ISR.<\/td><\/tr><tr><td><strong>Cutting\/Scoring Balloons<\/strong><\/td><td>Use blades or wires to incise the tough, elastic restenotic tissue, allowing more effective expansion. Used as pretreatment before DCB or repeat DES to enhance efficacy.<\/td><\/tr><tr><td><strong>Repeat DES<\/strong><\/td><td>Implanting a second (usually thinner-strut) DES. While effective, it creates a &#8220;sandwich&#8221; of metal layers, which may increase the risk of future re-restenosis or thrombosis.<\/td><\/tr><tr><td><strong>Atherectomy<\/strong><\/td><td>Rotational or Orbital atherectomy may be used if the restenotic tissue is heavily calcified, though it is less common for ISR than for native lesions.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">C. Advanced and Surgical Options<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Vascular Brachytherapy (VBT):<\/strong> Localized radiation therapy used for &#8220;recalcitrant&#8221; ISR (cases that have failed multiple DES and DCB attempts). It inhibits fibroblast and SMC proliferation.<\/li>\n\n\n\n<li class=\"\"><strong>CABG:<\/strong> Coronary Artery Bypass Grafting is considered if there is multivessel disease, involving the Left Main, or if the ISR is diffuse and has failed multiple percutaneous interventions.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n","protected":false},"excerpt":{"rendered":"<p>In-stent restenosis (ISR) remains a significant challenge in interventional cardiology, characterized by the narrowing of a previously stented coronary artery segment. While Drug-Eluting Stents (DES) have drastically reduced its incidence compared to Bare-Metal Stents (BMS), it still occurs in roughly 5\u201310% of modern DES implantations. Pathophysiology The underlying mechanism of ISR is essentially an exaggerated [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":66414,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[9],"tags":[],"class_list":["post-66411","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Coronary In-Stent Restenosis (ISR) - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Coronary In-Stent Restenosis (ISR) - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"In-stent restenosis (ISR) remains a significant challenge in interventional cardiology, characterized by the narrowing of a previously stented coronary artery segment. While Drug-Eluting Stents (DES) have drastically reduced its incidence compared to Bare-Metal Stents (BMS), it still occurs in roughly 5\u201310% of modern DES implantations. Pathophysiology The underlying mechanism of ISR is essentially an exaggerated [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-12T01:23:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-12T01:23:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/03\/Coronary-In-Stent-Restenosis-ISR.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1203\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Coronary In-Stent Restenosis (ISR)\",\"datePublished\":\"2026-03-12T01:23:04+00:00\",\"dateModified\":\"2026-03-12T01:23:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/\"},\"wordCount\":555,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Coronary-In-Stent-Restenosis-ISR.jpg\",\"articleSection\":[\"General Cardiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/\",\"name\":\"Coronary In-Stent Restenosis (ISR) - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Coronary-In-Stent-Restenosis-ISR.jpg\",\"datePublished\":\"2026-03-12T01:23:04+00:00\",\"dateModified\":\"2026-03-12T01:23:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Coronary-In-Stent-Restenosis-ISR.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/Coronary-In-Stent-Restenosis-ISR.jpg\",\"width\":1203,\"height\":675},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/coronary-in-stent-restenosis-isr\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Coronary In-Stent Restenosis (ISR)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Coronary In-Stent Restenosis (ISR) - All About Cardiovascular System and Disorders","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/","og_locale":"en_US","og_type":"article","og_title":"Coronary In-Stent Restenosis (ISR) - All About Cardiovascular System and Disorders","og_description":"In-stent restenosis (ISR) remains a significant challenge in interventional cardiology, characterized by the narrowing of a previously stented coronary artery segment. While Drug-Eluting Stents (DES) have drastically reduced its incidence compared to Bare-Metal Stents (BMS), it still occurs in roughly 5\u201310% of modern DES implantations. Pathophysiology The underlying mechanism of ISR is essentially an exaggerated [&hellip;]","og_url":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2026-03-12T01:23:04+00:00","article_modified_time":"2026-03-12T01:23:06+00:00","og_image":[{"width":1203,"height":675,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/03\/Coronary-In-Stent-Restenosis-ISR.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Coronary In-Stent Restenosis (ISR)","datePublished":"2026-03-12T01:23:04+00:00","dateModified":"2026-03-12T01:23:06+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/"},"wordCount":555,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/03\/Coronary-In-Stent-Restenosis-ISR.jpg","articleSection":["General Cardiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/","url":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/","name":"Coronary In-Stent Restenosis (ISR) - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/03\/Coronary-In-Stent-Restenosis-ISR.jpg","datePublished":"2026-03-12T01:23:04+00:00","dateModified":"2026-03-12T01:23:06+00:00","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/03\/Coronary-In-Stent-Restenosis-ISR.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/03\/Coronary-In-Stent-Restenosis-ISR.jpg","width":1203,"height":675},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/coronary-in-stent-restenosis-isr\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Coronary In-Stent Restenosis (ISR)"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/66411","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=66411"}],"version-history":[{"count":3,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/66411\/revisions"}],"predecessor-version":[{"id":66415,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/66411\/revisions\/66415"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/66414"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=66411"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=66411"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=66411"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}