{"id":67163,"date":"2026-05-23T15:43:09","date_gmt":"2026-05-23T10:13:09","guid":{"rendered":"https:\/\/johnsonfrancis.org\/professional\/?p=67163"},"modified":"2026-05-23T15:43:10","modified_gmt":"2026-05-23T10:13:10","slug":"hemodynamic-changes-in-cardiac-tamponade","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/","title":{"rendered":"Hemodynamic Changes in Cardiac Tamponade"},"content":{"rendered":"<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/yN2IwAVy3eg?si=Qv9mUosryMByZJ2A\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n\n<p class=\"wp-block-paragraph\">Cardiac tamponade is fundamentally a mechanical problem: the accumulation of pericardial fluid under high pressure restricts the heart&#8217;s ability to fill during diastole. This creates a state of fixed cardiac volume, leading to severe, progressive hemodynamic compromise.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Diastolic Pressure Equalization<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The definitive hemodynamic hallmark of cardiac tamponade is the <strong>equalization of diastolic pressures<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\">As intrapericardial pressure rises, it eventually exceeds the normal filling pressures of the cardiac chambers.<\/li>\n\n\n\n<li class=\"\">During diastole, the right atrial (RA), right ventricular end-diastolic (RVEDP), left atrial (LA), and left ventricular end-diastolic pressures (LVEDP) all converge to match the elevated pericardial pressure (typically 15\u201320 mmHg).<\/li>\n\n\n\n<li class=\"\">This eliminates the normal pressure gradients that drive diastolic filling, drastically reducing preload and stroke volume.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">2. The Absent <em>y<\/em> Descent<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Normally, the right atrium fills during ventricular systole (producing the <em>x<\/em> descent on a central venous pressure tracing) and empties rapidly into the right ventricle when the tricuspid valve opens in early diastole (producing the <em>y<\/em> descent).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In tamponade, this filling pattern is severely altered:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Prominent <em>x<\/em> descent:<\/strong> Atrial filling can still occur during ventricular systole because the contracting ventricles briefly decrease in volume, creating a small amount of space within the tight pericardial sac.<\/li>\n\n\n\n<li class=\"\"><strong>Blunted or absent <em>y<\/em> descent:<\/strong> As soon as the tricuspid valve opens, the elevated pericardial pressure completely prevents the right ventricle from expanding. Early diastolic filling halts immediately, abolishing the normal drop in atrial pressure.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">3. Ventricular Interdependence and Pulsus Paradoxus<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Because the tense pericardial sac fixes the total volume of the heart, the left and right ventricles are forced to compete for space. This creates an exaggerated form of <strong>ventricular interdependence<\/strong>, clinically observed as pulsus paradoxus (an inspiratory drop in systolic blood pressure greater than 10 mmHg).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Inspiration:<\/strong> Negative intrathoracic pressure increases venous return to the right atrium and right ventricle.<\/li>\n\n\n\n<li class=\"\"><strong>The Septal Shift:<\/strong> Because the RV cannot expand outward against the rigid fluid collection, the interventricular septum is forced to bow to the left.<\/li>\n\n\n\n<li class=\"\"><strong>The Hemodynamic Hit:<\/strong> This septal bowing encroaches on the left ventricular cavity, severely decreasing LV end-diastolic volume. The result is an immediate drop in left-sided stroke volume and systemic systolic blood pressure during inspiration.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Cardiac tamponade is fundamentally a mechanical problem: the accumulation of pericardial fluid under high pressure restricts the heart&#8217;s ability to fill during diastole. This creates a state of fixed cardiac volume, leading to severe, progressive hemodynamic compromise. 1. Diastolic Pressure Equalization The definitive hemodynamic hallmark of cardiac tamponade is the equalization of diastolic pressures. 2. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":67164,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[9],"tags":[],"class_list":["post-67163","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Hemodynamic Changes in Cardiac Tamponade - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hemodynamic Changes in Cardiac Tamponade - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"Cardiac tamponade is fundamentally a mechanical problem: the accumulation of pericardial fluid under high pressure restricts the heart&#8217;s ability to fill during diastole. This creates a state of fixed cardiac volume, leading to severe, progressive hemodynamic compromise. 1. Diastolic Pressure Equalization The definitive hemodynamic hallmark of cardiac tamponade is the equalization of diastolic pressures. 2. [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-23T10:13:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-23T10:13:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/05\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1203\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Hemodynamic Changes in Cardiac Tamponade\",\"datePublished\":\"2026-05-23T10:13:09+00:00\",\"dateModified\":\"2026-05-23T10:13:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/\"},\"wordCount\":356,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg\",\"articleSection\":[\"General Cardiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/\",\"name\":\"Hemodynamic Changes in Cardiac Tamponade - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg\",\"datePublished\":\"2026-05-23T10:13:09+00:00\",\"dateModified\":\"2026-05-23T10:13:10+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg\",\"width\":1203,\"height\":675},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/hemodynamic-changes-in-cardiac-tamponade\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Hemodynamic Changes in Cardiac Tamponade\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Hemodynamic Changes in Cardiac Tamponade - All About Cardiovascular System and Disorders","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/","og_locale":"en_US","og_type":"article","og_title":"Hemodynamic Changes in Cardiac Tamponade - All About Cardiovascular System and Disorders","og_description":"Cardiac tamponade is fundamentally a mechanical problem: the accumulation of pericardial fluid under high pressure restricts the heart&#8217;s ability to fill during diastole. This creates a state of fixed cardiac volume, leading to severe, progressive hemodynamic compromise. 1. Diastolic Pressure Equalization The definitive hemodynamic hallmark of cardiac tamponade is the equalization of diastolic pressures. 2. [&hellip;]","og_url":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2026-05-23T10:13:09+00:00","article_modified_time":"2026-05-23T10:13:10+00:00","og_image":[{"width":1203,"height":675,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/05\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Hemodynamic Changes in Cardiac Tamponade","datePublished":"2026-05-23T10:13:09+00:00","dateModified":"2026-05-23T10:13:10+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/"},"wordCount":356,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/05\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg","articleSection":["General Cardiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/","url":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/","name":"Hemodynamic Changes in Cardiac Tamponade - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/05\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg","datePublished":"2026-05-23T10:13:09+00:00","dateModified":"2026-05-23T10:13:10+00:00","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/05\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/05\/Hemodynamic-Changes-in-Cardiac-Tamponade.jpg","width":1203,"height":675},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/hemodynamic-changes-in-cardiac-tamponade\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Hemodynamic Changes in Cardiac Tamponade"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/67163","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=67163"}],"version-history":[{"count":2,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/67163\/revisions"}],"predecessor-version":[{"id":67166,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/67163\/revisions\/67166"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/67164"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=67163"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=67163"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=67163"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}