{"id":67746,"date":"2026-07-12T18:13:36","date_gmt":"2026-07-12T12:43:36","guid":{"rendered":"https:\/\/johnsonfrancis.org\/professional\/?p=67746"},"modified":"2026-07-12T18:13:40","modified_gmt":"2026-07-12T12:43:40","slug":"echocardiographic-evaluation-of-aortic-stenosis","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/","title":{"rendered":"Echocardiographic Evaluation of Aortic Stenosis"},"content":{"rendered":"<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/dpEzTVO8B3k?si=ctZWAP-CxHThyYOl\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n\n<p class=\"wp-block-paragraph\">Echocardiographic evaluation of Aortic Stenosis (AS) requires a multi-parametric approach, synthesizing 2D valve morphology, meticulous Doppler hemodynamics, and the impact of the stenosis on the left ventricle.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Morphological Assessment (2D &amp; 3D Echo)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Before dropping the Doppler gate, careful 2D assessment determines the etiology and lays the groundwork for accurate measurements.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"\"><strong>Parasternal Long Axis (PLAX):<\/strong> Assess for restricted systolic opening, leaflet thickening, and calcification. This view is critical for measuring the Left Ventricular Outflow Tract (LVOT) diameter, which must be measured in mid-systole, inner-edge to inner-edge, 0.5 to 1.0 cm proximal to the valve annulus.<\/li>\n\n\n\n<li class=\"\"><strong>Parasternal Short Axis (PSAX):<\/strong> Identifies leaflet morphology (bicuspid vs. tricuspid vs. unicuspid), though heavy calcification can obscure the commissures.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">2. Hemodynamic Quantification (Doppler)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The core of AS grading relies on precise Doppler interrogations. Multiple acoustic windows (apical, right parasternal, suprasternal) must be interrogated with a dedicated non-imaging Continuous Wave (CW) probe (PEDOF) to ensure alignment parallel to the highest velocity jet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">The Continuity Equation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The calculation of Aortic Valve Area (AVA) relies on the conservation of mass principle, assuming stroke volume at the LVOT equals stroke volume at the aortic valve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AVA = (CSA<sub>LVOT<\/sub> x VTI<sub>LVOT<\/sub>)\/VTI<sub>AV<\/sub><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because the LVOT Cross-Sectional Area (CSA<sub>LVOT<\/sub>) is derived from the diameter (D<sub>LVOT<\/sub>):<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CSA<sub>LVOT<\/sub> = \u03c0 x (D<sub>LVOT<\/sub>\/2)<sup>2<\/sup><\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Clinical Pitfall:<\/strong> Because the LVOT diameter is squared in the equation, a 2 mm measurement error can shift the calculated AVA by up to 30%, easily reclassifying a moderate AS as severe.<\/p>\n<\/blockquote>\n\n\n\n<h3 class=\"wp-block-heading\">Dimensionless Index (Velocity Ratio)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When LVOT diameter cannot be measured accurately, the velocity ratio removes the spatial dimension and isolates the hemodynamic step-up:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DI = (V<sub>max, LVOT<\/sub>)\/(V<sub>max, AV<\/sub>) or (VTI<sub>LVOT<\/sub>)\/(VTI<sub>AV<\/sub>)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A value of &lt; 0.25 strongly suggests severe AS, regardless of the LVOT measurement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Diagnostic Criteria for Severe AS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">According to standard ASE\/EACVI guidelines, the combination of the following criteria defines severe, high-gradient aortic stenosis in the presence of normal LV function:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Parameter<\/strong><\/td><td><strong>Moderate AS<\/strong><\/td><td><strong>Severe AS<\/strong><\/td><\/tr><\/thead><tbody><tr><td><strong>Peak Velocity (V<sub>max<\/sub>)<\/strong><\/td><td>3.0 &#8211; 3.9 m\/s<\/td><td>\u2265 4.0 m\/s<\/td><\/tr><tr><td><strong>Mean Gradient (\u0394P<sub>mean<\/sub>)<\/strong><\/td><td>20 &#8211; 39 mmHg<\/td><td>\u2265 40 mmHg<\/td><\/tr><tr><td><strong>Aortic Valve Area (AVA)<\/strong><\/td><td>1.0 &#8211; 1.5 cm<sup>2<\/sup><\/td><td>\u2264 1.0 cm<sup>2<\/sup><\/td><\/tr><tr><td><strong>Indexed AVA (AVAi)<\/strong><\/td><td>0.6 &#8211; 0.85 cm<sup>2<\/sup>\/m<sup>2<\/sup><\/td><td>\u2264 0.6 cm<sup>2<\/sup>\/m<sup>2<\/sup><\/td><\/tr><tr><td><strong>Dimensionless Index (DI)<\/strong><\/td><td>0.25 &#8211; 0.50<\/td><td>&lt; 0.25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">4. The Discordant Grading Challenge (LFLG)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The diagnostic pathway becomes complex when criteria are discordant\u2014most commonly when the <strong>AVA is \u2264 1.0 cm<sup>2<\/sup><\/strong> but the <strong>mean gradient is &lt; 40 mmHg<\/strong>. This requires evaluating flow status, defined by a Stroke Volume Index (SVi) &lt; 35 mL\/m<sup>2<\/sup>.<\/p>\n\n\n\n<ol start=\"1\" class=\"wp-block-list\">\n<li class=\"\"><strong>Classical Low-Flow, Low-Gradient (LFLG) AS:<\/strong> Depressed LVEF (&lt; 50%).\n<ul class=\"wp-block-list\">\n<li class=\"\"><em>Next step:<\/em> Low-dose Dobutamine Stress Echo (DSE) to differentiate true severe AS (fixed valve area with flow augmentation) from pseudo-severe AS (valve opens further as stroke volume increases).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li class=\"\"><strong>Paradoxical Low-Flow, Low-Gradient AS:<\/strong> Preserved LVEF (\u2265 50%) but low SVi due to a small, hypertrophied, stiff LV cavity with impaired filling (often seen in elderly, hypertensive patients).\n<ul class=\"wp-block-list\">\n<li class=\"\"><em>Next step:<\/em> Integration of CT Calcium Scoring (> 2000 AU in men, > 1200 AU in women strongly supports severe AS).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li class=\"\"><strong>Normal-Flow, Low-Gradient Severe AS:<\/strong> SVi \u2265 35 mL\/m<sup>2<\/sup> with AVA \u2264 1.0 cm<sup>2<\/sup> and gradient &lt; 40 mmHg. This is frequently due to measurement errors (underestimating LVOT diameter) or represents a moderate AS with a small body surface area.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Echocardiographic evaluation of Aortic Stenosis (AS) requires a multi-parametric approach, synthesizing 2D valve morphology, meticulous Doppler hemodynamics, and the impact of the stenosis on the left ventricle. 1. Morphological Assessment (2D &amp; 3D Echo) Before dropping the Doppler gate, careful 2D assessment determines the etiology and lays the groundwork for accurate measurements. 2. Hemodynamic Quantification [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":67747,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[9],"tags":[],"class_list":["post-67746","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Echocardiographic Evaluation of Aortic Stenosis - All About Cardiovascular System and Disorders<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Echocardiographic Evaluation of Aortic Stenosis - All About Cardiovascular System and Disorders\" \/>\n<meta property=\"og:description\" content=\"Echocardiographic evaluation of Aortic Stenosis (AS) requires a multi-parametric approach, synthesizing 2D valve morphology, meticulous Doppler hemodynamics, and the impact of the stenosis on the left ventricle. 1. Morphological Assessment (2D &amp; 3D Echo) Before dropping the Doppler gate, careful 2D assessment determines the etiology and lays the groundwork for accurate measurements. 2. Hemodynamic Quantification [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-12T12:43:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-12T12:43:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/07\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1348\" \/>\n\t<meta property=\"og:image:height\" content=\"756\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Echocardiographic Evaluation of Aortic Stenosis\",\"datePublished\":\"2026-07-12T12:43:36+00:00\",\"dateModified\":\"2026-07-12T12:43:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/\"},\"wordCount\":507,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg\",\"articleSection\":[\"General Cardiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/\",\"name\":\"Echocardiographic Evaluation of Aortic Stenosis - All About Cardiovascular System and Disorders\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg\",\"datePublished\":\"2026-07-12T12:43:36+00:00\",\"dateModified\":\"2026-07-12T12:43:40+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg\",\"width\":1348,\"height\":756},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/echocardiographic-evaluation-of-aortic-stenosis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Echocardiographic Evaluation of Aortic Stenosis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Echocardiographic Evaluation of Aortic Stenosis - All About Cardiovascular System and Disorders","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/","og_locale":"en_US","og_type":"article","og_title":"Echocardiographic Evaluation of Aortic Stenosis - All About Cardiovascular System and Disorders","og_description":"Echocardiographic evaluation of Aortic Stenosis (AS) requires a multi-parametric approach, synthesizing 2D valve morphology, meticulous Doppler hemodynamics, and the impact of the stenosis on the left ventricle. 1. Morphological Assessment (2D &amp; 3D Echo) Before dropping the Doppler gate, careful 2D assessment determines the etiology and lays the groundwork for accurate measurements. 2. Hemodynamic Quantification [&hellip;]","og_url":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2026-07-12T12:43:36+00:00","article_modified_time":"2026-07-12T12:43:40+00:00","og_image":[{"width":1348,"height":756,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/07\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Echocardiographic Evaluation of Aortic Stenosis","datePublished":"2026-07-12T12:43:36+00:00","dateModified":"2026-07-12T12:43:40+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/"},"wordCount":507,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/07\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg","articleSection":["General Cardiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/","url":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/","name":"Echocardiographic Evaluation of Aortic Stenosis - All About Cardiovascular System and Disorders","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/07\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg","datePublished":"2026-07-12T12:43:36+00:00","dateModified":"2026-07-12T12:43:40+00:00","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/07\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2026\/07\/Echocardiographic-Evaluation-of-Aortic-Stenosis.jpg","width":1348,"height":756},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/echocardiographic-evaluation-of-aortic-stenosis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Echocardiographic Evaluation of Aortic Stenosis"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/67746","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=67746"}],"version-history":[{"count":3,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/67746\/revisions"}],"predecessor-version":[{"id":67750,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/67746\/revisions\/67750"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/67747"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=67746"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=67746"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=67746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}