{"id":7304,"date":"2012-04-22T16:07:28","date_gmt":"2012-04-22T16:07:28","guid":{"rendered":"http:\/\/cardiophile.org\/?p=7304"},"modified":"2023-07-14T19:13:03","modified_gmt":"2023-07-14T13:43:03","slug":"reel-syndrome-vs-pacemaker-twiddler-syndrome","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/","title":{"rendered":"Reel syndrome vs pacemaker twiddler syndrome"},"content":{"rendered":"<p><iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/SQnbMn7djmc\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\"><\/iframe><\/p>\n<h2><span style=\"color: #008000;\">Reel syndrome vs pacemaker twiddler syndrome<\/span><\/h2>\n<p><span style=\"color: #0000ff;\">Pacemaker twiddler syndrome is characterized by coiling of the pacemaker lead due to rotation of the pulse generator of the pacemaker system along its<span style=\"color: #ff00ff;\"> long axis<\/span>.<\/span> This is seen in those with a lax skin and subcutaneous tissue like in the elderly. A large loose subcutaneous pocket may predispose to it especially in those who are likely to twiddle with the device in its pocket. <span style=\"color: #ff00ff;\">Reel syndrome is a variant in which the pulse generator rotates on its <span style=\"color: #0000ff;\">transverse axis<\/span> leading to coiling of the lead around the generator and loss of capture due to retraction of the lead from the heart.<\/span> It is mentioned that damage to the lead like fracture and insulation breakage are more likely with twiddler syndrome than reel syndrome.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.<\/p>\n","protected":false},"author":1,"featured_media":60234,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[6],"tags":[],"class_list":["post-7304","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ecg-electrophysiology"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reel syndrome vs pacemaker twiddler&#039;s syndrome<\/title>\n<meta name=\"description\" content=\"Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reel syndrome vs pacemaker twiddler&#039;s syndrome\" \/>\n<meta property=\"og:description\" content=\"Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2012-04-22T16:07:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-14T13:43:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2012\/04\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"895\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Reel syndrome vs pacemaker twiddler syndrome\",\"datePublished\":\"2012-04-22T16:07:28+00:00\",\"dateModified\":\"2023-07-14T13:43:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/\"},\"wordCount\":136,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg\",\"articleSection\":[\"ECG \\\/ Electrophysiology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/\",\"name\":\"Reel syndrome vs pacemaker twiddler's syndrome\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg\",\"datePublished\":\"2012-04-22T16:07:28+00:00\",\"dateModified\":\"2023-07-14T13:43:03+00:00\",\"description\":\"Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#primaryimage\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg\",\"contentUrl\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg\",\"width\":1200,\"height\":895},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/reel-syndrome-vs-pacemaker-twiddler-syndrome\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reel syndrome vs pacemaker twiddler syndrome\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reel syndrome vs pacemaker twiddler's syndrome","description":"Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/","og_locale":"en_US","og_type":"article","og_title":"Reel syndrome vs pacemaker twiddler's syndrome","og_description":"Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.","og_url":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2012-04-22T16:07:28+00:00","article_modified_time":"2023-07-14T13:43:03+00:00","og_image":[{"width":1200,"height":895,"url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2012\/04\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg","type":"image\/jpeg"}],"author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Reel syndrome vs pacemaker twiddler syndrome","datePublished":"2012-04-22T16:07:28+00:00","dateModified":"2023-07-14T13:43:03+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/"},"wordCount":136,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2012\/04\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg","articleSection":["ECG \/ Electrophysiology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/","url":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/","name":"Reel syndrome vs pacemaker twiddler's syndrome","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#primaryimage"},"thumbnailUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2012\/04\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg","datePublished":"2012-04-22T16:07:28+00:00","dateModified":"2023-07-14T13:43:03+00:00","description":"Reel syndrome: pulse generator rotates on its transverse axis and lead coils around the generator, retracting from the heart, causing loss of capture.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#primaryimage","url":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2012\/04\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg","contentUrl":"https:\/\/johnsonfrancis.org\/professional\/wp-content\/uploads\/2012\/04\/Reel-Syndrome-vs-Pacemaker-Twiddler-Syndrome-1.jpg","width":1200,"height":895},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/reel-syndrome-vs-pacemaker-twiddler-syndrome\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Reel syndrome vs pacemaker twiddler syndrome"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/7304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=7304"}],"version-history":[{"count":5,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/7304\/revisions"}],"predecessor-version":[{"id":60239,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/7304\/revisions\/60239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media\/60234"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=7304"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=7304"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=7304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}