{"id":9838,"date":"2008-12-14T17:58:33","date_gmt":"2008-12-14T17:58:33","guid":{"rendered":"http:\/\/cardiophile.org\/?p=776"},"modified":"2008-12-14T17:58:33","modified_gmt":"2008-12-14T17:58:33","slug":"impella-percutaneous-left-ventricular-assist-device","status":"publish","type":"post","link":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/","title":{"rendered":"Impella percutaneous left ventricular assist device"},"content":{"rendered":"<h2><span style=\"color: #008000;\">Impella percutaneous left ventricular assist device<\/span><\/h2>\n<p>Impella percutaneous left ventricular assist device: Impella LP 2.5 manufactured by Abiomed-Impella CardioSystems GmbH, Aachen, Germany is percutaneous left ventricular assist device. It uses a catheter-based miniaturized rotary blood pump, that is placed retrogradely through the aortic valve. The microaxial pump aspirates blood from the left ventricle and expels it to the ascending aorta with a maximal flow of 2.5 L\/min. It may be used to tide over a crisis situation in patients with cardiogenic shock of reversible etiology. Efficacy Study of LV Assist Device to Treat Patients With Cardiogenic Shock (ISAR-SHOCK) using this device has been completed. It was a comparison between in intra aortic balloon pump (IABP) and Impella LP 2.5 left ventricular assist device in acute coronary syndrome with cardiogenic shock. A report of the trial in the November 4, 2008 issue of JACC [1] mentions that the cardiac index (CI) after 30 minutes of support was significantly increased in patients with the Impella LP2.5 compared with patients with IABP (Impella: CI = 0.49 \u00b1 0.46 l\/min\/m2; IABP: CI = 0.11 \u00b1 0.31 l\/min\/m2; p = 0.02). Mortality benefit has not been demonstrated yet [2].<\/p>\n<p>Recover\u00ae LP 2.5 is a minimally invasive ventricular unloading catheter which can introduced percutaneously through the femoral artery and provides a flow of 2.5 litres per minute. Recover\u00ae LP 5.0 is a ventricular unloading catheter, which is placed via a femoral artery cut-down into the left ventricle and can support a flow of 5 litres per minute.<\/p>\n<p><strong><span style=\"color: #0000ff;\">References<\/span><\/strong><\/p>\n<ol>\n<li>Melchior Seyfarth, Dirk Sibbing, Iris Bauer, Georg Fr\u00f6hlich, Lorenz Bott-Fl\u00fcgel, Robert Byrne, Josef Dirschinger, Adnan Kastrati, Albert Sch\u00f6mig. <a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/19007597\/\">A randomized clinical trial to evaluate the safety and efficacy of a percutaneous left ventricular assist device versus intra-aortic balloon pumping for treatment of cardiogenic shock caused by myocardial infarction<\/a>. J Am Coll Cardiol. 2008 Nov 4;52(19):1584-8.<\/li>\n<li>Health Quality Ontario. <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC5313122\/\">Percutaneous Ventricular Assist Devices: A Health Technology Assessment<\/a>. Ont Health Technol Assess Ser. 2017 Feb 7;17(2):1-97. eCollection 2017.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.<\/p>\n","protected":false},"author":1,"featured_media":38595,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","footnotes":""},"categories":[18],"tags":[],"class_list":["post-9838","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-angiography-and-interventions"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Impella percutaneous left ventricular assist device - 2.5 &amp; 5.0<\/title>\n<meta name=\"description\" content=\"Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Impella percutaneous left ventricular assist device - 2.5 &amp; 5.0\" \/>\n<meta property=\"og:description\" content=\"Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/\" \/>\n<meta property=\"og:site_name\" content=\"All About Cardiovascular System and Disorders\" \/>\n<meta property=\"article:published_time\" content=\"2008-12-14T17:58:33+00:00\" \/>\n<meta name=\"author\" content=\"Johnson Francis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Johnson Francis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/\"},\"author\":{\"name\":\"Johnson Francis\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"headline\":\"Impella percutaneous left ventricular assist device\",\"datePublished\":\"2008-12-14T17:58:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/\"},\"wordCount\":317,\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"articleSection\":[\"Angiography and Interventions\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/\",\"name\":\"Impella percutaneous left ventricular assist device - 2.5 & 5.0\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2008-12-14T17:58:33+00:00\",\"description\":\"Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/impella-percutaneous-left-ventricular-assist-device\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Impella percutaneous left ventricular assist device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#website\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/\",\"name\":\"All About Cardiovascular System and Disorders\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/#\\\/schema\\\/person\\\/5441d907049b914770f4bd98fb57feec\",\"name\":\"Johnson Francis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\",\"caption\":\"Johnson Francis\"},\"logo\":{\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g\"},\"description\":\"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal\",\"url\":\"https:\\\/\\\/johnsonfrancis.org\\\/professional\\\/author\\\/jf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Impella percutaneous left ventricular assist device - 2.5 & 5.0","description":"Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/","og_locale":"en_US","og_type":"article","og_title":"Impella percutaneous left ventricular assist device - 2.5 & 5.0","og_description":"Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.","og_url":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/","og_site_name":"All About Cardiovascular System and Disorders","article_published_time":"2008-12-14T17:58:33+00:00","author":"Johnson Francis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Johnson Francis","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#article","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/"},"author":{"name":"Johnson Francis","@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"headline":"Impella percutaneous left ventricular assist device","datePublished":"2008-12-14T17:58:33+00:00","mainEntityOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/"},"wordCount":317,"publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#primaryimage"},"thumbnailUrl":"","articleSection":["Angiography and Interventions"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/","url":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/","name":"Impella percutaneous left ventricular assist device - 2.5 & 5.0","isPartOf":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#website"},"primaryImageOfPage":{"@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#primaryimage"},"image":{"@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#primaryimage"},"thumbnailUrl":"","datePublished":"2008-12-14T17:58:33+00:00","description":"Impella percutaneous left ventricular assist device: uses a catheter-based miniaturized rotary blood pump, placed retrogradely through the aortic valve.","breadcrumb":{"@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/johnsonfrancis.org\/professional\/impella-percutaneous-left-ventricular-assist-device\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/johnsonfrancis.org\/professional\/"},{"@type":"ListItem","position":2,"name":"Impella percutaneous left ventricular assist device"}]},{"@type":"WebSite","@id":"https:\/\/johnsonfrancis.org\/professional\/#website","url":"https:\/\/johnsonfrancis.org\/professional\/","name":"All About Cardiovascular System and Disorders","description":"","publisher":{"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/johnsonfrancis.org\/professional\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":["Person","Organization"],"@id":"https:\/\/johnsonfrancis.org\/professional\/#\/schema\/person\/5441d907049b914770f4bd98fb57feec","name":"Johnson Francis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g","caption":"Johnson Francis"},"logo":{"@id":"https:\/\/secure.gravatar.com\/avatar\/80861b82c3f559be9e413245c5643b6c483c93495507facfe32cf96ccd8bcffd?s=96&d=mm&r=g"},"description":"Former Professor of Cardiology, Calicut Govt. Medical Kozhikode, Kerala, India. Editor-in-Chief, BMH Medical Journal","url":"https:\/\/johnsonfrancis.org\/professional\/author\/jf\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/9838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/comments?post=9838"}],"version-history":[{"count":0,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/posts\/9838\/revisions"}],"wp:attachment":[{"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/media?parent=9838"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/categories?post=9838"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/johnsonfrancis.org\/professional\/wp-json\/wp\/v2\/tags?post=9838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}